Skip to content

Energy management: from data to decisions.

Make your energy consumption visible, make sense of the data with AI, and manage your cost and efficiency decisions from a single platform with Voltie.

BEFORE VOLTIE
WITH VOLTIE
OUR PARTNERS

Companies that trust us with their energy

Acarsan Pazarlama ve San. A.Ş.
Acarsan Pazarlama ve San. A.Ş.
Aquamarin
Aquamarin
Avcı Gıda
Avcı Gıda
Bentcam
Bentcam
Folkart Hills Çeşme
Folkart Hills Çeşme
Forbest Liva
Forbest Liva
Gimiloğulları
Gimiloğulları
Mevsim Market
Mevsim Market
PERDER Ege
PERDER Ege
Ulupınar Shopping Center
Ulupınar Shopping Center
Viyana Kahvesi
Viyana Kahvesi

Your electricity bill shouldn’t be a guess

Energy is a line item that grows every year, yet most facilities only find out what they used when the bill lands at month end. Voltie compares the raw data coming off your meter with the bill, finds the difference and wins it back for you.

Live consumption monitoring

You see your consumption on screen as it happens, not on a bill at month end. Instantaneous power, the daily load curve and the per-site breakdown all sit on one screen.

See the dashboard

Bill verification

We recalculate loss-and-theft charges, distribution fees, taxes and reactive items against current regulation. If there is a discrepancy, your formal objection letter comes ready as well.

How we calculate it

Reactive power and compensation monitoring

You are alerted as your inductive and capacitive ratios approach the limit, so you can act before a penalty is issued. Preventing those penalties is one of the things we set out to do.

How penalties get to zero

Tariff and supplier comparison

We run the numbers on your own hourly load profile, not on generic price lists. You see which supplier is genuinely cheaper, then make the call.

See the simulation
Reporting, alert management and carbon footprint accounting are part of the same dashboard. All features
HOW IT WORKS

From the day we connect to your panel to your first saving

DAY 1

We connect to your panel

Our IoT module attaches to the meter you already have. No meter swap, no production stop. Modbus, M-Bus and pulse output are supported; the uplink is GSM or Wi-Fi.

FIRST WEEK

Data starts flowing

Readings start flowing. Your shift, weekend and seasonal patterns are learned and your facility’s load profile takes shape. Every calculation that follows rests on it.

FIRST MONTH

Bill and tariff analysis

We scan your last 12 months of bills, check every line item against our own measurements and work out what you overpaid. Supplier offers are simulated on the same profile.

ONGOING

Alerts and savings

You get a notification when the reactive limit gets close, when peak-hour usage drifts or when a meter goes quiet. The monthly report arrives with a list of actions.

Field installation· Konak Store connecting
Existing panel Voltie IoT Modbus · GSM cloud
Installation time: 40 minutes on average, no downtime
Load profile forming· 7 days live
Instantaneous power128 kW
Today1,842 kWh
Refreshlive
00:0012:0017:00 peak23:00
Seven days is enough to build the site profile; forecasts are calculated from it.
Bill verification· August 20263 findings
Active energy142,380 ₺142,380 ₺
Loss & theft charge12,940 ₺+4,812 ₺
Distribution charge18,220 ₺
Reactive penalties6,410 ₺+6,410 ₺
VAT base34,650 ₺+1,170 ₺
Overpaid: 12,392 ₺ — objection letter ready
Monthly outcome· 6-month trend monitoring
Cost−18%
Reactive penalties0 ₺
Alerts24
MarAprMay JunJulAug
!14:20 — 38% deviation during peak hours, chiller unit 3
SERVING THE STANDARD

The measurement side of an ISO 50001 system

In Türkiye, industrial sites consuming more than 1,000 TOE a year are legally required to run a TS EN ISO 50001 energy management system, and efficiency incentives ask for the certificate as well. The hardest part of that certificate is measurement — what gets measured, how often, and how the record is kept. That is exactly where Voltie works.

Clause 6.6 — Energy data collection

Meter and IoT data is collected continuously, with no manual entry. Raw index readings stay in the dashboard; any period you choose exports to Excel exactly as it is.

Clause 9.1 — Monitoring, measurement and analysis

Consumption, power factor and peak demand are monitored live. A deviation shows up on the chart the moment it happens, not on the bill at the end of the month.

Clause 9.3 — Management review

At the start of every month, consumption, cost and unit price are gathered into a single document alongside earlier periods — ready to go to management as input.

Clause 10.1 — Corrective action

Unexpected consumption, a meter gone quiet or a power factor limit being approached all arrive as notifications; what drifted, and when, stays on the record.

Managerial requirements — energy policy, objectives, competence, internal audit — are not a piece of software’s job; they stay with you. Voltie takes on the measurement, monitoring and record side. Explore the platform

See Voltie on your own data

Leave your work email and we’ll get back to you. We’ll go through your facility’s consumption together and show you where the savings are.

Have a look at the frequently asked questions.

Frequently asked questions →